Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Chromatogr A ; 1526: 119-127, 2017 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-29111101

RESUMO

In this study, a QuEChERS (Quick, Easy, Cheap, Effective, Rugged and Safe) method, optimized by a 23 full factorial design, was developed for the determination of 72 pesticides in plant parts of carrot, corn, melon, rice, soy, silage, tobacco, cassava, lettuce and wheat by ultra-high-performance liquid chromatographic tandem mass spectrometry (UHPLC-MS/MS). Considering the complexity of these matrices and the need of use calibration in matrix, a new calibration approach based on single level standard addition in the sample (SLSAS) was proposed in this work and compared with the matrix-matched calibration (MMC), the procedural standard calibration (PSC) and the diluted standard addition calibration (DSAC). All approaches presented satisfactory validation parameters with recoveries from 70 to 120% and relative standard deviations≤20%. SLSAS was the most practical from the evaluated approaches and proved to be an effective way of calibration. Method limit of detection were between 4.8 and 48µgkg-1 and limit of quantification were from 16 to 160µgkg-1. Method application to different kinds of plants found residues of 20 pesticides that were quantified with z-scores values≤2 in comparison with other calibration approaches. The proposed QuEChERS method combined with UHPLC-MS/MS analysis and using an easy and effective calibration procedure presented satisfactory results for pesticide residues determination in different crop plants and is a good alternative for routine analysis.


Assuntos
Cromatografia Líquida de Alta Pressão , Produtos Agrícolas/química , Análise de Alimentos/métodos , Praguicidas/análise , Espectrometria de Massas em Tandem , Calibragem , Análise de Alimentos/economia , Análise de Alimentos/normas , Limite de Detecção , Resíduos de Praguicidas/análise , Reprodutibilidade dos Testes
2.
J Chromatogr A ; 1514: 36-43, 2017 Sep 08.
Artigo em Inglês | MEDLINE | ID: mdl-28774714

RESUMO

In this study, the efficiency of a new fluorinated sorbent for dispersive solid-phase extraction (d-SPE) clean-up in extracts provided by the QuEChERS (Quick, Easy, Cheap, Effective, Rugged and Safe) acetate method from tomato and sweet pepper samples was evaluated by ultra-high performance liquid chromatography tandem mass spectrometry (UHPLC-MS/MS). Clean-up using d-SPE technique has been widely used associated with the QuEChERS method. The most commonly sorbents used in d-SPE are primary secondary amine (PSA), octadecylsilane (C18) and graphitized carbon black (GCB), which are indicated to remove sugars, fatty acids, pigments, among others. The performance of an alternative fluorinated sorbent was compared with PSA and C18 sorbents for representative pesticides and better results were obtained when the fluorinated sorbent was used. Validation presented acceptable results for trueness and precision, with method limit of detection between 0.9 and 1.8µgkg-1 and limit of quantification from 2.6 to 5.4µgkg-1. Most of the compounds presented low matrix effect. Results showed that the fluorinated sorbent contribute to the clean-up of the tomato extract and is an effective alternative, with lower costs and greater efficiency. Commercial tomato samples were analyzed using the proposed method and residues of dimethoate, tetraconazole and thiamethoxam were detected.


Assuntos
Cromatografia Líquida de Alta Pressão , Resíduos de Praguicidas/análise , Espectrometria de Massas em Tandem , Adsorção , Aminas/química , Fluoretação , Limite de Detecção , Resíduos de Praguicidas/isolamento & purificação , Silanos/química , Extração em Fase Sólida , Fuligem/química
3.
J AOAC Int ; 99(6): 1426-1435, 2016 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-27642168

RESUMO

Most of the analytical methods currently applied in food control laboratories are focused on the determination of target compounds using LC coupled to tandem MS, which is an effective technique, but low-resolution MS is limited. Thus, a method for determination of pesticide multiresidues in fruits (pear, apple, and grape) using a modified quick, easy, cheap, effective, rugged, and safe method and LC coupled to quadrupole time-of-flight (Q-TOF) MS was developed and validated. The proposed method showed good linearity (r2 > 0.99) from 1 to 100 µg/L. Recoveries for blank samples spiked at 0.01, 0.04, and 0.10 mg/kg were between 66 and 122%, with RSDs <28%. Respective LOQs for apple, pear, and grape matrixes were 0.01 mg/kg for 112, 120, and 118 compounds, and 0.04 mg/kg for 22, 12, and 17 compounds, and average mass accuracy error was 3.2 ppm. LC with Q-TOF MS detection using protonated molecular ion and/or adducts and mass accuracy provided reliability for the method. The proposed method is effective for pesticide residue determination in apple, pear, and grape samples, proving that high-resolution MS using full scan mode can be a powerful and reliable technique for quantification purposes, being adequate for application in the surveillance of maximum residue limits set by different legislations.


Assuntos
Contaminação de Alimentos/análise , Malus/química , Resíduos de Praguicidas/análise , Pyrus/química , Vitis/química , Cromatografia Líquida , Espectrometria de Massas
4.
J Chromatogr A ; 1460: 84-91, 2016 Aug 19.
Artigo em Inglês | MEDLINE | ID: mdl-27432791

RESUMO

Among calibration approaches for organic compounds determination in complex matrices, external calibration, based in solutions of the analytes in solvent or in blank matrix extracts, is the most applied approach. Although matrix matched calibration (MMC) can compensates the matrix effects, it does not compensate low recovery results. In this way, standard addition (SA) and procedural standard calibration (PSC) are usual alternatives, despite they generate more sample and/or matrix blanks consumption need, extra sample preparations and higher time and costs. Thus, the goal of this work was to establish a fast and efficient calibration approach, the diluted standard addition calibration (DSAC), based on successive dilutions of a spiked blank sample. In order to evaluate the proposed approach, solvent calibration (SC), MMC, PSC and DSAC were applied to evaluate recovery results of grape blank samples spiked with 66 pesticides. Samples were extracted with the acetate QuEChERS method and the compounds determined by ultra-high performance liquid chromatography tandem mass spectrometry (UHPLC-MS/MS). Results indicated that low recovery results for some pesticides were compensated by both PSC and DSAC approaches. Considering recoveries from 70 to 120% with RSD <20% as adequate, DSAC presented 83%, 98% and 100% of compounds meeting this criteria for the spiking levels 10, 50 and 100µgkg(-1), respectively. PSC presented same results (83%, 98% and 100%), better than those obtained by MMC (79%, 95% and 97%) and by SC (62%, 70% and 79%). The DSAC strategy showed to be suitable for calibration of multiresidue determination methods, producing adequate results in terms of trueness and is easier and faster to perform than other approaches.


Assuntos
Cromatografia Líquida de Alta Pressão , Compostos Orgânicos/análise , Espectrometria de Massas em Tandem , Calibragem , Cromatografia Líquida de Alta Pressão/normas , Compostos Orgânicos/isolamento & purificação , Compostos Orgânicos/normas , Resíduos de Praguicidas/análise , Resíduos de Praguicidas/isolamento & purificação , Resíduos de Praguicidas/normas , Extração em Fase Sólida , Solventes/química , Espectrometria de Massas em Tandem/normas
5.
Water Sci Technol ; 73(12): 2944-52, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27332840

RESUMO

The aim of this work was to investigate the kinetics of removal of clomazone herbicide from an aqueous solution by electrocoagulation. The experiments were performed in a cylindrical batch reactor with six aluminum electrodes in monopolar mode, arranged in series and connected to a digital DC power. The aqueous solution (tap water + clomazone) with initial pH close to 7.9 was always treated at ambient temperature (≈20 °C) and atmospheric pressure for 5,400 s. For a confidence level of 95% the rate constant of electrocoagulation and the efficiency of removal of clomazone at equilibrium were 2.1 × 10(-3) ± 0.5 × 10(-3) s(-1) and 97.7 ± 2.2%, respectively. The final chemical oxygen demand was 88% lower than that measured initially, while turbidity and apparent color were totally removed from the synthetic solution at a rate close to that of formation of aluminum hydroxides. Some reaction intermediates, such as benzonitrile-2-chloro and 2-chloro-hex-2,4-diene-1,6-dioic-acid determined by gas chromatography mass spectrometry (GC-MS) analysis, explain the ratio of equilibrium to initial total organic carbon approximately between 0.6 and 0.8 at a probability of 95%.


Assuntos
Herbicidas/química , Isoxazóis/química , Oxazolidinonas/química , Eliminação de Resíduos Líquidos/métodos , Poluentes Químicos da Água/química , Alumínio/análise , Eletricidade , Eletrodos , Eliminação de Resíduos Líquidos/instrumentação
6.
Food Chem ; 196: 25-33, 2016 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-26593461

RESUMO

In this study, different extraction procedures based on the QuEChERS method were compared for the multiresidue determination of pesticides in orange juice by ultra high performance liquid chromatography coupled to tandem mass spectrometry (UHPLC-MS/MS). After choosing preliminary conditions, an experimental design was carried out with the variables C18, PSA, NaOH and CH3COONa to optimize the sample preparation step. The validation results of the validation were satisfactory, since the method presented recoveries between 70% and 118%, with RSD lower than 19% for spike levels between 10 and 100 µg L(-1). The method limit of detection (LOD) and limit of quantification (LOQ) ranged from 3.0 to 7.6 µg L(-1) and from 4.9 to 26 µg L(-1), respectively. The method developed was adequate for the determination of 74 pesticide residues in orange juice.


Assuntos
Bebidas/análise , Cromatografia Líquida de Alta Pressão/métodos , Citrus sinensis/química , Resíduos de Praguicidas/química , Espectrometria de Massas em Tandem/métodos , Resíduos de Praguicidas/análise
7.
J AOAC Int ; 97(4): 987-94, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25145127

RESUMO

Pollution of water sources by pesticides is a result of intensive use of these compounds, and the establishment of analytical methods for monitoring programs is very important. This paper presents a method for the determination of multiclass pesticide residues in rice paddy water based on SPE and GC/MS/MS. The validation results were satisfactory. All compounds showed adequate linearity (r2 >or= 0.99), and analysis by GC/MS/MS with a triple quadrupole mass spectrometer gave high selectivity and sensitivity. With the proposed SPE step an LOD of 0.06 microg/L was achieved. Recoveries from blank samples spiked at 0.2, 04, and 0.8 microg/L were between 70 and 120% with RSD <20% for most analyzed compounds, despite their different chemical nature, indicating good accuracy and precision. The proposed method is efficient for pesticide residue determination, including some metabolites, and gave good performance when applied to real samples.


Assuntos
Oryza , Resíduos de Praguicidas/análise , Poluentes Químicos da Água/análise , Água/química , Cromatografia Gasosa-Espectrometria de Massas
8.
Chemosphere ; 107: 74-82, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24875873

RESUMO

A modified version of the QuEChERS method has been evaluated for the determination of 21 pharmaceuticals and 6 personal care products (PPCPs) in drinking-water sludge samples by employing ultra high liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). The performance of the method was evaluated through linearity, recovery, precision (intra-day), method detection and quantification limits (MDL and MQL) and matrix effect. The calibration curves prepared in acetonitrile and in the matrix extract showed a correlation coefficient ranging from 0.98 to 0.99. MQLs values were on the ng g(-1) order of magnitude for most compounds. Recoveries between 50% and 93% were reached with RSDs lower than 10% for most compounds. Matrix effect was almost absent with values lower than 16% for 93% of the compounds. By coupling a quick and simple extraction called QuEChERS with the UPLC-MS/MS analysis, a method that is both selective and sensitive was obtained. This methodology was successfully applied to real samples and caffeine and benzophenone-3 were detected in ng g(-1) levels.


Assuntos
Fracionamento Químico/métodos , Cosméticos/isolamento & purificação , Água Potável/química , Preparações Farmacêuticas/isolamento & purificação , Segurança , Esgotos/química , Purificação da Água/métodos , Cromatografia Líquida de Alta Pressão , Cosméticos/análise , Preparações Farmacêuticas/análise , Espectrometria de Massas por Ionização por Electrospray , Espectrometria de Massas em Tandem , Poluentes Químicos da Água/análise , Poluentes Químicos da Água/isolamento & purificação , Purificação da Água/economia
9.
Talanta ; 116: 827-34, 2013 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-24148481

RESUMO

Endocrine Disrupter Compounds (EDCs) are responsible for alterations in the endocrine system functions. Aquatic organisms are able to accumulate EDCs residues, being the major source of contamination for top predators and human consumers. This study aimed to develop and validate a method for the determination of 40 EDCs in fish fillet using modified QuEChERS and Gas Chromatography coupled with Mass Spectrometry in tandem (GC-MS/MS). A factorial design was used to optimize the extraction procedure. Method validation presented recoveries from 70.1% to 120.0% with RSD<20% and method limit of detection ranged from 0.3 to 7.5 µg kg(-1), showing good accuracy and precision. This method was successfully applied to the analysis of fish fillet from different species and residues of bisphenol A, chlorpyrifos and bifenthrin were detected. The proposed method proved to be effective for the determination of EDCs in fish fillet at very low concentration levels.


Assuntos
Compostos Benzidrílicos/isolamento & purificação , Clorpirifos/isolamento & purificação , Disruptores Endócrinos/isolamento & purificação , Produtos Pesqueiros/análise , Fenóis/isolamento & purificação , Piretrinas/isolamento & purificação , Espectrometria de Massas em Tandem/métodos , Poluentes Químicos da Água/isolamento & purificação , Animais , Análise Fatorial , Peixes , Cromatografia Gasosa-Espectrometria de Massas , Humanos , Limite de Detecção
10.
Anal Bioanal Chem ; 405(24): 7697-709, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23995504

RESUMO

Pollution of drinking water supplies from industrial waste is a result of several industrial processes and disposal practices, and the establishment of analytical methods for monitoring organic compounds related to environmental and health problems is very important. In this work, a method using solid-phase extraction (SPE) and gas chromatography coupled to triple quadrupole tandem mass spectrometry (GC-QqQ-MS/MS) was developed and validated for the simultaneous determination of pesticide residues and related compounds in drinking and surface water as well as in industrial effluent. Optimization of the method was achieved by using a central composite design approach on parameters such as the sample pH and SPE eluent composition. A single SPE consisting of the loading on a polymeric sorbent of 100 mL of sample adjusted to pH 3 and elution with methanol/methylene chloride (10:90, v/v) permitted the obtaining of acceptable recoveries in most cases. The concentration factor associated with sensitivity of the chromatographic analysis permitted the achievement of the method limit of detection values between 0.01 and 0.25 µg L(-1). Recovery assays presented mean recoveries between 70 and 120% for most of the compounds with very good precision, despite the different chemical nature of the compounds analyzed. The selectivity of the method, evaluated through the relative intensity of quantification and qualification ions obtained by GC-QqQ-MS/MS, was considered adequate. The developed method was finally applied to the determination of target analytes in real samples. River water and treated industrial effluent samples presented residues of some compounds, but no detectable residues were found in the drinking water samples evaluated.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...